Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur

Product Details
Customization: Available
Max.Head: 50-80m
Max.Capacity: >400 L/min
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

  • Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
  • Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
  • Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
  • Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
  • Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
  • Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
Find Similar Products

Basic Info.

Model NO.
GD50-50
Driving Type
Motor
Material
Cast Iron
Structure
Single-stage Pump
Assembly
Pipeline Pump
Power
Electric
Start Up
Electric Pump
Type
Centrifugal Pump
Application
Clarified Water Pump, Oil Transfer Pump, Chemical Pump
Industry
Air Conditioning Pump
Media
Clean Water
Performance
No Leakage Pump
Theory
Centrifugal Pump
Feature
Durable
Accept OEM or Not
Yes
Impeller Type
Closed
Frequency
50/60Hz
Transport Package
Plywood Casing
Specification
GD
Trademark
ATACH
Origin
China
HS Code
8413709990
Production Capacity
5000unit/Year

Product Description

Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur


- Name of pump:Vertical single stage pipeline water pump for  fire fighting system

- Pump Type: inline Pump

- Pump model:GD50-50

- Pump brand: ATACH

-Installation Type: vertical Close-Coupled 

- Impeller Quantity: 1 pcs

- Rated pump capacity: 18 m3/h

- Rated pump head: 50 m

- Power/speed: 5.5 Kw/2900 r.p.m

- Power supply:3 phase/380V/50HZ
(also supply special voltage,special frequency, explosion-proof motor, High efficiency and energy saving motor )

- Material Supply: Cast Iron Casing ,Stainless Steel 304 Impeller

- Shaft Seal: Mechanical seal

- Inlet / outlet : 50mm*50mm

- NPSH: 3.5  m

- Main usage:
1.Refrigeration
2.Air Conditioning System
3.Cooling Tower
4.Garden Fountains
5.Fire Fighting System
6.Building Water Supply
7.Water Pressurization

Application and characteristics:
Pipeline centrifugal pump is directly installed in the pipeline, and pressurizes the delivered medium.  Pipeline centrifugal pumps produced by this factory have small volume, light weight and compact structure.  They can be operated in single unit or connected in series (based on working pressure of the pump), and can be installed and used in a horizontal or vertical way. 
GD-type pump is single-stage single-suction centrifugal pump, for delivering clear water under normal temperature or medium with physical and chemical properties similar to clear water's.  They are mainly used in refrigerating, and air-conditioning system, cooling tower, garden fountain, fire-fighting and general water supply system. 
Please select GDR hot water pipeline pump if the medium temperature is over 80C, and select GDF type corrosion resistance pipeline pump under corrosive circumstances.



If you need other specifications or parameters of GD series Pipeline Centrifugal Pump, please contact us in detail.

Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur

Gd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation PressurGd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation PressurGd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation PressurGd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation PressurGd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation PressurGd50-50 Single-Stage Single-Suction Centrifugal Pump Is Used for Pressurizing Water Supply in High-Rise Buildings and Other Cold, Warm Water Circulation Pressur
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now